<doi_batch xmlns="http://www.crossref.org/schema/4.4.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" version="4.4.0"><head><doi_batch_id>38c40382-9b46-4c59-8369-20391a5ddcf7</doi_batch_id><timestamp>20250805132414796</timestamp><depositor><depositor_name>wseas:wseas</depositor_name><email_address>mdt@crossref.org</email_address></depositor><registrant>MDT Deposit</registrant></head><body><journal><journal_metadata language="en"><full_title>WSEAS TRANSACTIONS ON BIOLOGY AND BIOMEDICINE</full_title><issn media_type="electronic">2224-2902</issn><issn media_type="print">1109-9518</issn><archive_locations><archive name="Portico"/></archive_locations><doi_data><doi>10.37394/23208</doi><resource>http://wseas.org/wseas/cms.action?id=4011</resource></doi_data></journal_metadata><journal_issue><publication_date media_type="online"><month>1</month><day>7</day><year>2025</year></publication_date><publication_date media_type="print"><month>1</month><day>7</day><year>2025</year></publication_date><journal_volume><volume>22</volume><doi_data><doi>10.37394/23208.2025.22</doi><resource>https://wseas.com/journals/bab/2025.php</resource></doi_data></journal_volume></journal_issue><journal_article language="en"><titles><title>Near-field Resonance Microwave Imaging for Fibrosis Detection in Patients with Dupuytren Disease</title></titles><contributors><person_name sequence="first" contributor_role="author"><given_name>Andrew K.</given_name><surname>Martusevich</surname><affiliation>Lobachevsky University, Nizhny Novgorod, 603005, RUSSIA</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>Vladimir V.</given_name><surname>Nazarov</surname><affiliation>Lobachevsky University, Nizhny Novgorod, 603005, RUSSIA</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>Sergey V.</given_name><surname>Petrov</surname><affiliation>Lobachevsky University, Nizhny Novgorod, 603005, RUSSIA</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>Tatiana B.</given_name><surname>Kondratyeva</surname><affiliation>Sechenov University, Moscow, 119048, RUSSIA</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>Tatiana V.</given_name><surname>Khlevchuk</surname><affiliation>Sechenov University, Moscow, 119048, RUSSIA</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>Vera S.</given_name><surname>Badyanova</surname><affiliation>Lobachevsky University, Nizhny Novgorod, 603005, RUSSIA</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>Sergey P.</given_name><surname>Peretyagin</surname><affiliation>Association of Russian Ozone Therapy, Nizhny Novgorod, 603109, RUSSIA</affiliation></person_name></contributors><jats:abstract xmlns:jats="http://www.ncbi.nlm.nih.gov/JATS1"><jats:p>The purpose of this study was to analyze the possibility of detecting and evaluating the characteristics of fibrosis of palmar aponeurosis tissues in Dupuytren's disease using near-field resonant microwave sensing. The study involved 12 patients who underwent an examination before undergoing surgical treatment. The dielectric characteristics of the skin and underlying tissues were evaluated at 4 points, one of which was obviously in an unchanged area, and the rest in a potentially fibrous area. Near-field microwave sensing was performed using a proprietary hardware and software complex that included applicators with a radiation penetration depth of 2 to 5 mm. It has been established that in the area of fibroly transformed palmar aponeurosis, the actual part of the dielectric constant decreases significantly, and this process occurs fairly evenly at various points of the pathological focus. Our studies have also shown that the depth of fibrosis in the examined patients with Dupuytren's disease is approximately 3.5 mm.</jats:p></jats:abstract><publication_date media_type="online"><month>8</month><day>5</day><year>2025</year></publication_date><publication_date media_type="print"><month>8</month><day>5</day><year>2025</year></publication_date><pages><first_page>415</first_page><last_page>419</last_page></pages><publisher_item><item_number item_number_type="article_number">38</item_number></publisher_item><ai:program xmlns:ai="http://www.crossref.org/AccessIndicators.xsd" name="AccessIndicators"><ai:free_to_read start_date="2025-08-05"/><ai:license_ref applies_to="am" start_date="2025-08-05">https://wseas.com/journals/bab/2025/a765108-030(2025).pdf</ai:license_ref></ai:program><archive_locations><archive name="Portico"/></archive_locations><doi_data><doi>10.37394/23208.2025.22.38</doi><resource>https://wseas.com/journals/bab/2025/a765108-030(2025).pdf</resource></doi_data><citation_list><citation key="ref0"><doi>10.1097/01.bth.0000186794.90431.a4</doi><unstructured_citation>I.T. Au-Yong, C.J. Wildin, J.J. Dias, R.E. Page, A review of common practice in Dupuytren surgery, Tech. Hand Up Extrem. Surg., vol. 9, iss. 4, 2005, pp. 178-187, doi: 10.1097/01.bth.0000186794.90431.a4. </unstructured_citation></citation><citation key="ref1"><unstructured_citation>T.N. Yashina, A.V. Afanasyev, Surgical treatment of finger and hand contractures in Dupuytren's disease and its relapses, Modern technologies of diagnosis, treatment and rehabilitation of injuries and diseases of the upper limb, Moscow, 2007, pp. 266-267. </unstructured_citation></citation><citation key="ref2"><unstructured_citation>I.Zh. Osmonaliev, G.I. Mikusev, R.F. Bajkeev et al., Visualization of the boundaries of Dupuytren's contracture distribution according to MRI data, Modern problems of science and education, iss. 2, 2013. </unstructured_citation></citation><citation key="ref3"><doi>10.1007/s001130050732</doi><unstructured_citation>P. Brenner, A. Krause-Bergmann, V.H. Van, Dupuytren contracture in North Germany. Epidemiological study of 500 cases, Unfallchirurg, vol. 104, iss. 4, 2001, pp. 303- 311, doi: 10.1007/s001130050732. </unstructured_citation></citation><citation key="ref4"><unstructured_citation>S.M. Gonzalez, R.I. Gonzalez, Dupuytrens disease, West. J. Med., vol. 152, iss. 4, 1990. pp. 430-433. </unstructured_citation></citation><citation key="ref5"><unstructured_citation>H.D. Skoff, The surgical treatment of Dupuytrens contracture: a synthesis of techniques, Plast. Reconstr. Surg., vol. 113, iss. 2, 2004, pp. 540-544. </unstructured_citation></citation><citation key="ref6"><unstructured_citation>A.M. Manko, N.G. Gubochkin, A.V. Trapeznikov, Treatment of patients with Dupuytren's contracture from the standpoint of microsurgery, State and prospects of development of military traumatology and orthopaedics, Saint-Petersburg, 1999, pp. 471-477. </unstructured_citation></citation><citation key="ref7"><unstructured_citation>A.V. Kostrov, A.B. Strikovskij, D.V. Yanin et al., Study of electrodynamic parameters of biological tissues, Almanac of clinical medicine, iss. 17-2, 2008, pp. 96-99. </unstructured_citation></citation><citation key="ref8"><doi>10.1615/critrevbiomedeng.2022042194</doi><unstructured_citation>A.K. Martusevich, V.V. Nazarov, A.V. Surovegina, A.V. Novikov, Near-field microwave tomography of biological tisssues: future perspectives, Critical Reviews in Biomedical Engineering, vol. 50, Iss. 4, 2022, pp. 1-12, doi: 10.1615/CritRevBiomedEng.2022042194. </unstructured_citation></citation><citation key="ref9"><unstructured_citation>A.N. Reznik, N.V. Yurasova, Near-field microwave tomography of biological media, Journal of technical physics, vol. 74, iss. 4, 2004, pp. 108-116. </unstructured_citation></citation><citation key="ref10"><unstructured_citation>E.B. Bogomolova, A.K. Martusevich, I.A. Klemenova et al., Application of modern methods of visualization in the assessment of the state and prediction of the development of pathological scars, Medicine, iss. 3, 2017, pp. 58-75. </unstructured_citation></citation><citation key="ref11"><doi>10.1103/physrevlett.98.269902</doi><unstructured_citation>K.P. Gaikovich, Subsurface near-field scanning tomography, Physical Review Letters, vol. 98, iss. 18, 2007, pp. 183902, doi: 10.1103/PhysRevLett.98.183902. </unstructured_citation></citation><citation key="ref12"><doi>10.1088/0031-9155/50/4/003</doi><unstructured_citation>Y. Hayashi, N. Miura, N. Shinyashiki, S. Yagihara, Free water content and monitoring of healing processes of skin burns studied by microwave dielectric spectroscopy in vivo, Phys. Med. Biol., vol. 50, iss. 4, 2005, pp. N8- N14, doi: 10.1088/0031-9155/50/4/003. </unstructured_citation></citation><citation key="ref13"><doi>10.1088/0031-9155/45/2/101</doi><unstructured_citation>V. Raicu, N. Kitagawa, A. Irimajiri, A quantitative approach to the dielectric properties of the skin, Phys. Med. Biol., vol. 45, iss. 2, 2000, pp. L1-L4, doi: 10.1088/0031-9155/45/2/101. </unstructured_citation></citation><citation key="ref14"><unstructured_citation>A.V. Arsenyev, A.N. Volchenko, L.V. Lihachyova, V.I. Pecherskij, Application of the RF-near-field sensing method in the diagnosis of biological objects, Journal scientific and technical of information technologies, mechanics and optics, iss. 2, 2011, pp. 154-157. </unstructured_citation></citation><citation key="ref15"><unstructured_citation>I.V. Turchin, Methods of optical biomedical imaging: from subcellular structures to tissues and organs, Advances in physical sciences, vol. 186, iss. 5, 2016, pp. 550–567. </unstructured_citation></citation><citation key="ref16"><doi>10.1088/0031-9155/47/1/402</doi><unstructured_citation>T. Sunaga, H. Ikehira, S. Furukawa et al., Measurement of the electrical properties of human skin and the variation among subjects with certain skin conditions, Phys. Med. Biol., vol. 47, iss. 1, 2002, pp. N11-N15, doi: 10.1088/0031-9155/47/1/402. </unstructured_citation></citation><citation key="ref17"><doi>10.1088/0031-9155/39/6/001</doi><unstructured_citation>T. Tamura, M. Tenhunen, T .Lahtinen et al., Modelling of the dielectric properties of normal and irradiated skin, Phys. Med. Biol., vol. 39, iss. 6, 1994, pp. 927–936, doi: 10.1088/0031-9155/39/6/001. </unstructured_citation></citation><citation key="ref18"><unstructured_citation>A.V. Kostrov, A.I. Smirnov, D.V. Yanin et al., Resonance near-field microwave diagnostics of inhomogeneous media. Gerald of RAS. Physical series, vol. 69, iss. 12, 2005, pp. 1716-1720. </unstructured_citation></citation><citation key="ref19"><unstructured_citation>A. Berger, A. Delbruck, P. Brenner, R. Hinzmann, Dupuytren's disease: pathobiochemistry and clinical management, Berlin, Heidelberg: Springer-Velard, 1994. 220 p. </unstructured_citation></citation><citation key="ref20"><doi>10.2217/ijr.12.25</doi><unstructured_citation>D. Warwick, A. Tomas, A. Bayat, Dupuytren's disease: overview of a common connective tissue disease with a focus on emerging treatment options, Int. Clin. Rheumatol., vol. 7, iss. 3, 2012, pp. 309-323, doi: 10.2217/IJR.12.25.</unstructured_citation></citation></citation_list></journal_article></journal></body></doi_batch>